Order No.
|
Range
|
Accuracy
|
Display
|
193-201
|
0-1in
|
±.0001in
|
.0001 reading is obtained with vernier.
|
193-211
|
0-1in
|
±.0001in
|
.0001 reading is obtained with vernier.
|
193-212
|
1-2in
|
±.0001in
|
.0001 reading is obtained with vernier.
|
193-213
|
2-3in
|
±.0001in
|
.0001 reading is obtained with vernier.
|
193-214
|
3-4in
|
±.00015in
|
.0001 reading is obtained with vernier.
|
193-415
|
4-5in
|
±.00015in
|
.0001 reading is obtained with vernier.
|
193-416
|
5-6in
|
±.00015in
|
.0001 reading is obtained with vernier.
|
193-417
|
6-7in
|
±.0002in
|
.0001 reading is obtained with vernier.
|
193-418
|
7-8in
|
±.0002in
|
.0001 reading is obtained with vernier.
|
193-419
|
8-9in
|
±.0002in
|
.0001 reading is obtained with vernier.
|
193-420
|
9-10in
|
±.00025in
|
.0001 reading is obtained with vernier.
|
193-421
|
10-11in
|
±.00025in
|
.0001 reading is obtained with vernier.
|
![]() |
Features:
|
Technical Data
| Counter Reading | 0.01mm or .001" |
| Graduation | 0.01mm, 0.001mm, .001" or .0001" |
| Flatness | 0.6mm / .000024" |
| Parallelism | (2+R/100)µm, R=max. range (mm) [.00008” + .00004” (L/4)]” L= max. range (inch) |
| Measuring Faces | Carbide tipped |