| Stem Length |
Stem Diameter |
Data Output |
Order No. Short Range |
Order No. Long Range |
| 0.670in / 17mm |
0.375inch |
No Output |
2033101 |
2033102* |
| 1.50in / 38mm |
0.375inch |
2033103 |
2033104 |
| 0.670in / 17mm |
8.0mm |
2033105 |
2033106* |
| 1.50in / 38mm |
8.0mm |
2033107 |
2033108 |
| 0.670in / 17mm |
0.375inch |
Digital Output 6pin(D.E1)
|
2033111 |
2033112* |
| 1.50in / 38mm |
0.375inch |
2033113 |
2033114 |
| 0.670in / 17mm |
8.0mm |
2033115 |
2033116* |
| 1.50in / 38mm |
8.0mm |
2033117 |
2033118 |
| 0.670in / 17mm |
0.375inch |
Digital Output with hold/
Reset- 10pin(E2)
|
2033121 |
2033122* |
| 1.50in / 38mm |
0.375inch |
2033123 |
2033124 |
| 0.670in / 17mm |
8.0mm |
2033125 |
2033126* |
| 1.50in / 38mm |
8.0mm |
2033127 |
2033128 |
*Long Range Indicator Stem Length is 0.870in / 22mm
|
|
Maxµm® III Digital Transducer**
|
| Transducer Type |
Stem Length |
Stem Diameter |
Short Range |
Long Range |
| Canister |
0.670inch / 17mm |
0.375inch |
2033091 |
2033092* |
| Canister |
1.5inch / 38mm |
0.3752 |
2033093 |
2033094 |
| Canister |
0.670inch / 17mm |
8.0mm |
2033095 |
2033096* |
| Canister |
1.5inch / 38mm |
8.0mm |
2033097 |
--- |
| Pencil |
Body Diameter=0.375 |
2033099 |
--- |
*Long Range Indicator Stem Length is 0.870in / 22mm
**DIGITAL TRANSDUCER MODELS 203309X REQUIRE AN ADAPTOR CABLE FOR USE WITH TRADITIONAL DEI_XXXXX Maxum and Maxum Plus Indicating units. See Adaptor Cable
|
|
Adaptor Cables-adapts Digital Transducers to DEI Remote Indicating Units
|
| Description |
Short Range |
Long Range |
For DEI with 6 pin split connector
|
2239080 |
--- |
For DEI with 8 pin round connector
|
--- |
2239081 |
|
Maxµm® III Remote Indicating Unit***
|
| Description |
Order No. |
No Digital Output Port
|
2033001 |
| Digital Output-6pin (D,E1) |
2033011 |
| Digital Output with Hold & Reset- 10pin (E2) |
2033021 |
| ***Maxµm® III Remote Indicating units are not compatible with traditional Remote Transducer models EAS-XXXX |
|
| Maxum®III Digital Indicators |
|
- Features both digital display for accuracy and readability and unique „fan“ analog display for trend and change
- User configurable in inch/ metric units, normal/reverse sensing, resolution, analog scale, and tolerance setup & display
- Both integral and remote readout versions available
- Data output – 3 formats – Maxum, serial, digimatic
- Auto-power down increases battery life – uses commercially available battery
- Dynamic Capabilities: min, max, TIR, hold, reset
- Digital sensing allows indicating unit to identify digital transducer type by range
- Digital transducers equipped with durable cable and spring strain relief design and includes right angle option clip
- Digital Transducer available in Canister or Pencil style
- Special options available, such as –setup mode or calibration lockout, remote external power, 4:5 ratio, 2.0 or 3.0 inch stem lengths, and more…..
- Easy to select and order and operate!
- IP54 protection
- Easy to select and order and operate!
|

|
| Maxum®III Indicators Dimensions |
 |
| A |
B |
C |
For short range indicators-Std. Stem Length
|
(±1.0mm/±.40in range indicators)
|
| 17mm/.670in |
36mm/1.42in |
63.5mm/250in |
| For long range indicators-Std. Stem Length |
| (±1.99mm/±.100in range indicators) |
| 22mm/.87in |
47mm/1.84in |
73mm/2.87in |
| For both short and long range-Long Stem Lengths |
| 38mm/1.5in |
57mm/2.25in |
84.6mm/3.33in |
| 51mm/2in* |
70mm/2.75 |
97.3mm/3.83in |
| 76mm/3in* |
95mm/3.75in |
123mm/4.83in |
|
| |
|
*Special Order Lengths |
| Technical Data |
| Models and Specifications |

Each Maxum®III includes a double-sided overlay set. (Each side shown above)
|
| |
|
|
| |
Short Range
|
Long Range
|
| Digital Range: |
|
|
Standard Range
|
±0.04in/±1.00mm |
±0.100in/±1.99mm |
Reduced Range
|
±0.0199in/±0.199mm |
None |
| Digital Resolution: |
0.0005in/0.005mm |
0.0005in/0.005mm |
(switchable)
|
0.0001in/0.001mm |
0.0001in/0.001mm |
| |
0.00005in/0.001 |
|
| |
0.00002in/0.0005mm |
|
| Analog Range: |
5 or 25 or 50 |
25 or 50 |
| Analog Resolution: |
0.001in/0.01mm |
0.001in/0.01mm |
(switchable)
|
0.0005in/0.005mm |
0.0005in/0.005mm |
| |
0.0001in/0.001mm |
|
| Total Spindle Travel: |
0.120in/3.04mm |
0.250in/6.35mm |
| Pre-Travelˆ: |
0.010in/0.3mm |
0.020in/0.5mm |
| Over-Travelˆ: |
0.030in/0.8mm |
0.030in/0.8mm |
| Accuracy: |
|
|
Standard Range
|
0.5% of Total Range |
0.35% of Total Range |
Reduced Range
|
0.25% of Total Range |
N/A |
| Repeatability: |
±One Least Digit |
±One Least Digit |
| Gaging Force: |
3-4ox/85-112 grams, preloaded |
| Operation Temperature: |
50° to 130°F/10° to 55°C |
| Storage Temperature: |
-4° to 149°F/-20° to 65°C |
| IP Rating: |
54 |
| Weight: |
approximately 385gm/13.6oz |
| Battery Life: |
approximately 4000 hours |
| Power: |
3.0 volt Lithium battery (type CR123A or equivalent) |
| Contact Point: |
(Normally furnished-PT223) for 0.375in dia. Stem, 0.250in long, |
| |
radiused tip, 4-48 thread; (EPT-1037-W1) for 8mm dia. Stem. |
| |
6mm ling, radiused tip, M2.5 thread |
| ˆ-dependant on standard or reduced range selected. Standard Range shown. |
|