<H1>Field Indicators -- MeasureNOW Shopping Cart</H1> <B>$33.00</B> -- <I>Magnaflux</I> <P> <table width="100%" cellspacing="0" cellpadding="0" bordercolor="#000080" border="1" id="table8"> <tbody> <tr> <td width="15%" valign="middle" bgcolor="#004020" align="center"><font face="Arial" color="#ffff40"><b><font size="2"> Order #</font></b></font></td> <td width="15%" valign="middle" bgcolor="#004020" align="center"> <font face="Arial" color="#ffff40"><b><font size="2"> Description</font></b></font></td> </tr> <tr> <td width="15%" bgcolor="#ffffff" align="center"> <font face="Arial"><span class="ContentLink"> <font size="2">2480</font></span></font></td> <td width="84%" bgcolor="#ffffff" align="center"> <font size="2" face="Arial"> <b> <p align="left"> MAGNAFLUX Generic Field Indicator:</p> </b></font> <font size="2" face="Arial"> </font><p align="left"><font size="2" face="Arial">The MAGNAFLUX general purpose field indicator is a rugged, pocket size, noncalibrated field indicator that measures 2 _&#8221; in diameter and perfect for field use. The field indicator is scaled +10 or -10 gauss from 0 center. Each division represents 1 gauss. The field indicator is used to determine if there is residual magnetism left in the part.</font></p> </td> </tr> <tr> <td width="15%" bgcolor="#ffffff" align="center"> <font face="Arial"><span class="ContentLink"> <font size="2">505056</font></span></font></td> <td width="84%" bgcolor="#ffffff" align="center"> <font size="2" face="Arial"> <b> <p align="left">10 Gauss Calibrated Field Indicator -</p> </b></font> <font size="2" face="Arial"> </font><p align="left"><font size="2" face="Arial">The MAGNAFLUX 10 Gauss Calibrated Field Indicator is calibrated field indicator has a scale range of +10 or &#8211;10 gauss from 0 center. Each large-scale division represents 1 gauss and the small divisions represent _ gauss. The 10 gauss calibrated field indicator is accurate to </font> <font size="2" face="Arial"> +</font><font size="2" face="Arial">/</font><font size="2" face="Arial">&#8722; </font> <font size="2" face="Arial"> 0.3 gauss.</font></p> </td> </tr> <tr> <td width="15%" bgcolor="#ffffff" align="center"> <font face="Arial"><span class="ContentLink"> <font size="2">105645</font></span></font></td> <td width="84%" bgcolor="#ffffff" align="center"> <font size="2" face="Arial"> <b> <p align="left">20 Gauss Calibrated Field Indicator -</p> </b></font> <font size="2" face="Arial"> </font><p align="left"><font size="2" face="Arial">The MAGNAFLUX 20 Gauss Calibrated Field Indicator is for general purpose use as may be required in various demagnetization specifications. Scaled +20 or &#8211;20 or minus, gauss from 0 center with large divisions at 2 gauss and small divisions at 1 gauss. The gauss field indicator will withstand exposure to fields as strong as 400 oersteds without affecting calibration and is accurate to +/- 0.5 gauss</font></p> </td> </tr> <tr> <td width="99%" bgcolor="#ffffff" align="center" colspan="2"> <i> <font face="Arial-BoldItalicMT"> <b> </b></font></i><p align="left"> <font face="Arial"><i><b> Note! </b> Calibration field indicators should be re-calibrated every 6 months.</i></font></p> </td> </tr> </tbody> </table><div align="center"><br /><p align="center"> <img width="552" height="166" border="0" align="middle" src="https://www.nexternal.com/bcmac/images/Magnaf1.jpg" alt="" /></p> <p align="left"><font size="2" face="Arial">Magnetic Field Indicators are used to check residual magnetism after magnetic particle testing</font><font size="2" face="Wingdings"> </font></p> <div align="left"><ul> <li> <font size="2" face="Arial"> Magnetic Particle Field Indicators are also known as gauss meters or magnetometers </font> </li> <li> <font size="2" face="Arial"> Quick and easy &#8211; Magnetic Particle Field indicators read the amount of residual magnetism left in a&nbsp; part quickly when the indicator arrow is placed against a magnetized part </font> </li> <li> <font size="2" face="Arial"> Magnetic Particle Field Indicators are available in both general purpose non-calibrated and calibrated models</font> </li> <li> <font size="2" face="Arial"> Field Indicators may be re-calibrated through MAGNAFLUX Authorized Service Centers</font></li> </ul> </div> <div align="left"><b><font size="2" face="Arial">Directions for Use:</font></b><br /><font size="2" face="Arial"> <p align="left">Place the field indicator near or directly against the object being tested. The lower rim of the indicator below the arrow is the most sensitive part of the meter and should be placed closest to the part being measured. Indicator should be placed near a position on the part that exhibits flux leakage &#8211; such as at the end of a bar shaped part. Magnetic polarity of the field is being measured by the direction of the pointer deflection on the center zero scale. A plus (+) indicates the meter has been presented to a North magnetic pole and minus (-) to a South Pole. The higher the reading, the stronger the magnetic field. Readings in gauss relate only to the magnitude of external leakage fields and should not be misconstrued as the flux density within the part.</p> </font> <font size="2" face="Arial"> <i><b> <p align="left">Note!</p> </b></i></font> <ul> <li> <font size="2" face="Arial"> If you place the indicator in a field strong enough it may throw it considerably off scale. </font> </li> <li><font size="2" face="Arial"> If your field indicator comes in contact with the field of a demagnetizing coil or within the effective field of a conductor carrying a heavy alternating current, it may become demagnetized.</font></li> </ul> </div> </div> </P> <P> <LI>Indicator: Generic Field Indicator; 10 Gauss Calibrated Field Indicator; 20 Gauss Calibrated Field Indicator</P> <P><B>Other products in the category <A HREF="http://www.nexternal.com/bcmac/Category45" TITLE="NDT">NDT</A>:</B> <BR clear=left><BR><LI><A HREF=http://www.nexternal.com/bcmac/Product748 TITLE="Hands Free Black Light">Hands Free Black Light</A> -- Magnaflux <BR clear=left><BR><LI><A HREF=http://www.nexternal.com/bcmac/Product566 TITLE="OPTIMAX 365 True UV-A LED Flashlight">OPTIMAX 365 True UV-A LED Flashlight</A> -- Measure Now <BR clear=left><BR><LI><A HREF=http://www.nexternal.com/bcmac/Product360 TITLE="Magnetizing Yoke Kits">Magnetizing Yoke Kits</A> -- Magnaflux <BR clear=left><BR><LI><A HREF=http://www.nexternal.com/bcmac/Product361 TITLE="Yoke Only">Yoke Only</A> -- Magnaflux <BR clear=left><BR><LI><A HREF=http://www.nexternal.com/bcmac/Product441 TITLE="Magnaflux Black Lights">Magnaflux Black Lights</A> -- Magnaflux <BR clear=left><BR><LI><A HREF=http://www.nexternal.com/bcmac/Product437 TITLE="Spectronics Black Lights">Spectronics Black Lights</A> -- Spectronics </P> <BR clear=left><BR><P><A HREF="http://www.nexternal.com/bcmac" TITLE="MeasureNOW Products">MeasureNOW Products</A></P> <BR clear=left><BR><BR><BR><BR> <BR><A HREF="http://www.measurenow.com">MeasureNOW</A> <BR>MeasureNOW <A HREF="http://www.nexternal.com" TITLE="shopping cart">shopping cart</A> powered by Nexternal

drill it, grind it, mill it, turn it . . .

. . . you still have to measure it.

 
 
 

For Assistance Contact:
The NOW
Team
Phone: 800-875-4243
Fax: 314-993-0405
Email: service@measurenow.com

Join Our Mailing List

 
 
Need Tooling?